节点文献

空调机异常噪声源的实验分析与诊断研究

Abnormal Noise Sources Identification and Control of the Wall-Mounted Air-Conditioner

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张筱璐黄其柏许智生袁骥轩

【Author】 ZHANG Xiao-lu,HUANG Qi-bai,XU Zhi-sheng,YUAN Ji-xuan(School of Mechanical Science and Engineering,Huazhong University of Science and Technology,Wuhan430074,China)

【机构】 华中科技大学机械科学与工程学院

【摘要】 通过频谱分析中的CPB和FFT分析方法,确定空调室内机异常噪声的来源和频谱特性与压缩机相关,再通过声强分析,对近场噪声源进行准确定位,测定室内异常噪声源分布,在室内机面板蒸发器表面,特别是铜管弯曲处。最后通过对异常噪声的产生机理分析与降噪原理研究,探索三种控制异常噪声的方法。

【Abstract】 The abnormal noise of air conditioner has serious negative influence on the acoustic environment of consumers.In this paper,firstly,based on the theory of spectrum analysis which mainly consists of CPB(Constant Percentage Bandwidth) analysis and FFT analysis,it is confirmed that the abnormal noise comes from the compressor.Then,through sound density analysis,it can be identified that the abnormal noise source is distributed on the evaporator surface,espetially,at the location where the copper tubes bend.Finally,through the mechanism analysis of the abnormal noise and the study of noise reduction principle,three methods for controlling the abnormal noise are proposed and discussed.

  • 【文献出处】 噪声与振动控制 ,Noise and Vibration Control , 编辑部邮箱 ,2009年03期
  • 【分类号】TM925.12
  • 【被引频次】9
  • 【下载频次】179
节点文献中: 

本文链接的文献网络图示:

本文的引文网络