节点文献

根管治疗中旋转镍钛锉安全使用次数的测试

Experiment of useful life of rotary nickel titanium hand files for root canal preparation

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 胡福玲舒展

【Author】 HU Fu-ling SHU Zhan

【机构】 中日友好医院高干门诊

【摘要】 目的探讨使用旋转镍钛锉进行根管治疗时的安全次数,明确护士在根管治疗时对镍钛锉的使用次数进行记录的重要性。方法选用PorTaper和FlexMaster镍钛锉对200颗离体牙进行根管预备。结果无论是ProIaper系统还是FlexMaster系统的镍钛锉,最少使用14次后发生折断,最多使用20次。不同的镍钛锉在正常情况下有95%的可能在使用15-18次时发生折断。结论每种镍钛锉正常情况下使用最好不超过14次。

【Abstract】 Objective To measure the useful life of rotary nickel titanium hand fries for root canal preparation before frac- tured,and to define the importance of recording the times of use.Methods A total of 200 extracted human teeth were divid- ed into two groups to simulate root canal preparation using niti files of ProTaper and FlexMaster.Each file was used until fractured.Results Either PreTaper or FlexMaster files fractured after being used at least 14 times and at most 20 times. There was 95% possibility of fracture when the files had been used 15-18 times.Conclusion Usually it is safe to use the files under 14 times.

  • 【文献出处】 中华护理杂志 ,Chinese Journal of Nursing , 编辑部邮箱 ,2009年02期
  • 【分类号】R781.05
  • 【被引频次】2
  • 【下载频次】142
节点文献中: 

本文链接的文献网络图示:

本文的引文网络