节点文献

厌氧流化床-外循环三相好氧流化床处理垃圾渗滤液

The Treatment of Landfill Leachate by Anaerobic Fluidized Bed-outside Circle Three-phase Aerobic Fluidized Bed

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 郭勇陈晓东杨平

【Author】 GUO Yong1,CHEN Xiao-dong1,YANG Ping2(1.School of Chem.Eng.,Sichuan Univ.,Chengdu 610065,China;2.School of Architecture and Environment,Sichuan Univ.,Chengdu 610065,China)

【机构】 四川大学化工学院四川大学建筑与环境学院

【摘要】 利用厌氧流化床-外循环三相好氧流化床联合系统处理垃圾渗滤液,分别考察了进水CODCr浓度、进水NH3-N浓度、厌氧段CODCr去除率和厌氧段NH3-N去除率等因素对垃圾渗滤液的CODCr和NH3-N的总去除率的影响。实验表明,联合系统对低NH3-N浓度的垃圾渗滤液具有较好的处理效果,当系统的总停留时间在10.5 h时,在进水CODCr浓度范围为2817.2~4383.88 mg/L,进水NH3-N浓度为303.12~445.43 mg/L,联合处理系统对CODCr去除率为86.79%~98.85%;对NH3-N的去除率为81.14%~94.01%。系统对CODCr去除的容积负荷平均达到7.38 kg/(m3.d),对NH3-N去除的容积负荷平均达到0.37 kg/(m3.d)。当垃圾渗滤液的CODCr值在3400 mg/L以下时,联合处理系统对其中的CODCr有较高的去除率,为86.79%~98.85%;当NH3-N浓度在400mg/L以下时,系统对NH3-N有较高的去除率,为81.14%~94.01%;厌氧段的CODCr和NH3-N去除率较高时,有利于提高联合处理系统的总CODCr和总NH3-N去除率。

【Abstract】 The landfill leachate was treated by the combination of anaerobic fluiized bed and outside circle three-phase aerobic fluidized bed systems.The influent CODCr concentration,influent NH3-N concentration,anaerobic CODCr removal rate,anaerobic NH3-N removal rate and other factors were studied on the CODCr and NH3-N removal rate of the Landfill Leachate.The experimental results showed that the landfill leachate of low NH3-N concentration has good treatment efficiency by the joint system,when the total HRT,influent CODCr concentration,influent NH3-N concentration of the treatment systems were 10.5 h,2817.2 ~ 4383.88 mg/L,303.12 ~ 445.43 mg/L,respectively,the removal rates of CODCr and NH3-N were 86.79% ~ 98.85% and 81.14% ~ 94.01%.The Volumetric loading for CODCr and NH3-N achieved an average of 7.38 kg/(m3·d) and 0.37 kg/(m3·d).When the CODCr value of Landfill Leachate below 3400 mg/L,there were high CODCr removal rate of 86.79%~98.85%,when NH3-N concentration below 400 mg/L,the NH3-N in the system had a higher removal rate of 81.14%~94.01%.It was proved that to improve the removal rate of anaerobic CODCr and NH3-N and reduce the NH3-N concentration of anaerobic effluent,will help improve the overall CODCr and total NH3-N removal rate of the combined systems.

【基金】 国家“十五”重大科技专项资助项目(2002AA601210)
  • 【文献出处】 四川大学学报(工程科学版) ,Journal of Sichuan University(Engineering Science Edition) , 编辑部邮箱 ,2009年06期
  • 【分类号】X703
  • 【被引频次】9
  • 【下载频次】259
节点文献中: 

本文链接的文献网络图示:

本文的引文网络