数字散斑法测量加载200N与500N股骨干骨折钢板固定下的位移

Digital Speckle Measuring of Bias on the Steel Pltae of Femoral Fractures with 200 and 500 Newton

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李建云姚激李钊肖丽波周轶平巴迎春陈英杰邹智荣

【Author】 (LI Jian-yun1*,YA-Li1*,XIAO Li-bo2*,LI Zhao3*,ZHOU Yi-ping 4*,BA Ying-chun5*,CHEN Ying-jie5#,ZOU Zhi-rong5#(1.Department of Mechanics,Kunming University of Science and Technology,Kunming,650224;2.Yunnan Center for Disease Prevention and Control,Kunming 650041;3.Department of Ophthalmology,Yunnan Province Second Hospital,Kunming,650021;4.Yunnan Key Laboratory of Pharmacology for Natural Products,Kunming Medical College,Kunming,650031;5.Department of Anatomy,Kunming Medical College,Kunming,650031)

【机构】 昆明理工大学工程力学系云南省疾病预防控制中心门诊云南省第二人民医院眼科昆明医学院云南省重点实验室昆明医学院人体解剖教研室

【摘要】 目的数字散斑法测试钢板螺钉的位移,为临床上分析螺钉断裂之原因提供理论依据。材料与方法取6根成人防腐股骨标本,于股骨干中点横行锯断,制造股骨干中段骨折模型。将骨折标本进行复位并使用10孔钢板加压固定,骨折线两端各使用5枚螺丝钉固定。设计成10种状态进行对比测量锁钉位移,分别是:a.模拟骨折愈合后的受力状态(钢板固定后,未锯断);b.骨折后加压钢板坚强内固定组;c.在b组基础上近端去一枚螺丝钉;d.在c组基础上远端去一枚螺丝钉;e.在d组基础上近端去一枚螺丝钉;f.在e组基础上远端去一枚螺丝钉;g.在f组基础上近端去一枚螺丝钉;h.在g组基础上远端去一枚螺丝钉;i.在h组的基础上近端去一枚螺丝钉;j.在i组基础上远端去一枚螺丝钉。在200 N、500N(牛顿)拉力下,电子万能试验机加载测量,相关软件计算位移。结果(1)螺丝钉1与10、2与9、3与8、4与7、5与6的比较差异无统计学意义(P>0.05),其余两两比较差异有统计学意义(P<0.05)。结论应选择6孔以上的钢板,以减少由于钢板的强度损失所引发的螺钉断裂。

【Abstract】 Objective The bias of the steel plate’s nail were measured of by the digital speckle method,a theoretical basis was provided for clinical fracture.Methods 6 femoral specimen were taken.The steel plate fixation model in the femur 1/2 was made.Ten conditions were designed simulating to compare the experimental model: a.the femur was not sawed with the compression steel plate fixed(integrity,simulation of the cured fracture);b.the internal fixation of compression steel plates(segmentation);c.a proximal screw was removed based on b;d.a distal screw was removed based on c;e.a proximal screw was removed based on d;f.a distal screw was removed based on e;g.a proximal screw was removed based on f;h.a distal screw was removed based on g;i.a proximal screw was removed based on h;j.a distal screw was removed based on i.Then the specimens were fixed and installed on electronic universal testing machine.Under the Rally of 200N and 500N(newton),the bias were calculated by the related software.Results There was no significance between screw 1 and 10、2 and 9、3 and 8、4 and 7、5 and 6(P>0.05),and the left were significant(P<0.05).Conclutions When the steel plate for the treatment of femoral shaft fracture is used,more than six pores of steel plate should be chosen to reduce its stability loss avoid leading to the breakage of screws.

【关键词】 股骨干骨折钢板内固定术生物力学
【Key words】 FemurFracturesteel plateInternal fixationBiomechanics
【基金】 云南省科技厅-昆明医学院联合专项基金资助项目(2007C0043R);云南省教育厅科学研究基金立项资助项目(07Z10199)
  • 【文献出处】 四川解剖学杂志 ,Sichuan Journal of Anatomy , 编辑部邮箱 ,2009年03期
  • 【分类号】R687.3
  • 【被引频次】1
  • 【下载频次】30
节点文献中: 

本文链接的文献网络图示:

本文的引文网络