节点文献
微波消解-石墨炉原子吸收光谱法测定奶粉中铜和锰
Determination of copper and manganese in milk powder by microwave digestion-graphite furnace atomic absorption spectrometry
【摘要】 建立密闭微波消解-石墨炉原子吸收光谱法测定奶粉中铜和锰质量分数。该方法简便快速、灵敏度高,回收率为91.2%~104.1%,相对标准偏差(RSD)为1.91%~4.93%,可以满足奶粉中铜和锰的测定要求。
【Abstract】 In this paper, we set up a method to determinate copper and manganese in milk powder by closed-vessel microwave digestion-graphite furnace atomic absorption spectrometry. The method was simple、rapid and high sensibility. The recovery was in the range of 91.2%~104.1%,RSD in the range of 1.91%~4.93%。 Its precision and accuracy met the demands of analysis.
【关键词】 石墨炉原子吸收光谱;
微波消解;
奶粉;
铜;
锰;
【Key words】 Graphite Furnace Atomic Absorption Spectrometry (GFAAS); microwave digestion; milk powder; copper; manganese;
【Key words】 Graphite Furnace Atomic Absorption Spectrometry (GFAAS); microwave digestion; milk powder; copper; manganese;
- 【文献出处】 中国乳品工业 ,China Dairy Industry , 编辑部邮箱 ,2009年11期
- 【分类号】TS252.7
- 【被引频次】5
- 【下载频次】200