核反应堆压力容器小破口事故中坍塌液位的测量
Liquid collapse level monitoring for nuclear reactors during loss of coolant accident
【摘要】 核反应堆冷却剂液位是重要的安全参数,而压力容器破口事故(LOCA)下更加需要测量坍塌液位来反映堆芯冷却状态。该文针对差压式液位测量方法在破口事故下的特性进行了理论分析和试验研究。分析表明:喷放附加压降和喷放引起的压力波振荡都可能造成对于差压式测量方法产生附加的扰动;其中以压力波影响为主。实验结果说明:压力波振荡等影响造成差压液位测量结果产生峰值不大于2.5%的附加误差,这在破口事故下属于测量精度允许范围。因此,差压方法在压力容器小破口事故下仍能正确反映容器内坍塌液位,即容器的液体装量。
【Abstract】 The coolant level is an important parameter for nuclear reactor cooling systems,especially in loss of coolant accidents(LOCA).The differential pressure characteristics of level meter during such accidents were studied theoriticlly and exeperimentally.The pressure waves and addition pressure drops are found to affect the measurements.The error caused by pressure waves is larger,but the experiments show that the total error will be less than 2.5%,which is acceptable for the loss of coolant accidents.Thus,the differential pressure gauges can provide accurate collapse level data,even during the accidents.
【Key words】 nuclear reactors; liquid level monitoring; lost of coolant accident(LOCA);
- 【文献出处】 清华大学学报(自然科学版) ,Journal of Tsinghua University(Science and Technology) , 编辑部邮箱 ,2009年06期
- 【分类号】TL364
- 【被引频次】2
- 【下载频次】230