节点文献

基于改进FBD法的谐波电流检测研究

The improved FBD method in harmonic current detection

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 司为国丁祖军李明

【Author】 SI Wei-guo1, DING Zu-jun2, LI Ming2(1.Jiangsu Electrical Power Company,Nanjing 210024,China;2.Department of Electrical Engineering, Southeast University, Nanjing 210096,China)

【机构】 江苏省电力公司东南大学电气工程学院

【摘要】 对谐波电流快速检测和跟踪的能力是有源电力滤波器补偿性能好坏的关键,为了能快速有效的检测出三相四线制系统中的谐波电流,本文在介绍传统FBD法的理论原理的基础上提出了一种改进的FBD法。它是将传统的FBD法经过一次线性变换,减少了其间的矩阵运算。该方法不受系统电压畸变的影响,可以明显减少原方法的计算量。理论分析和仿真以及实验结果证实了该方法的正确性和优越性。

【Abstract】 This paper issues a kind of improved FBD method based on traditional FBD method in order to detect harmonic current rapidly and efficiently in three phases four wires system because the ability of harmonic current detection and compensation is the key parameter of the Active Power Filter(APF).The method is improved by a linear transformation so that matrix operation is reduced.The new method is influenced little by voltage distortion.The analysis, simulation and experiment have proved the correctness and its priority.

  • 【文献出处】 电力系统保护与控制 ,Power System Protection and Control , 编辑部邮箱 ,2009年15期
  • 【分类号】TM711
  • 【被引频次】21
  • 【下载频次】231
节点文献中: 

本文链接的文献网络图示:

本文的引文网络