节点文献

分压电路方法测量直流高压高阻箱示值误差的测量不确定度的研究

Research on Measurement Uncertainty of DC High-voltage and High-resistance Box Error of Indication by RVD Circuit

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 董耀

【Author】 DONG Yao1,2 (1.Lanzhou Jiaotong University,Lanzhou 730070,China;2.Gansu Institute of Metrology,Lanzhou 730070,China)

【机构】 兰州交通大学甘肃省计量研究院

【摘要】 直流高压高阻箱是主要用于检定、校准绝缘电阻表和高阻计的计量标准器。提出电阻分压电路(RVD c ircu it)测量直流高压高阻箱的方法,同时给出测量原理图和计量标准装置的构成,并对分压组合电路测量直流高压高阻箱示值误差的测量不确定度进行了评定。

【Abstract】 DC high-voltage and high-resistance box is a kind of measurement standard,which is used mainly for verification and calibration of megohmmeter and high-resistance meter.The measurement method to RVD circuit of DC high-voltage and high-resistance box was proposed and the principle of measurements diagram and the composition of measurement standard were given.The uncertainty of DC high-voltage and high-resistance box error of indication by RVD circuit was evaluated.

  • 【文献出处】 化工自动化及仪表 ,Control and Instruments in Chemical Industry , 编辑部邮箱 ,2009年05期
  • 【分类号】TM934.1
  • 【被引频次】8
  • 【下载频次】90