节点文献

催化微电解—UASB处理羧甲基纤维素生产废水

Catalytic Microelectrolysis/UASB Process for Treatment of Carboxymethyl Cellulose Production Wastewater

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 潘碌亭束玉保罗华飞李璐缪强强

【Author】 PAN Lu-ting,SHU Yu-bao,LUO Hua-fei,LI Lu,MIAO Qiang-qiang(State Key Laboratory of Pollution Control and Resources Reuse,Tongji University,Shanghai 200092,China)

【机构】 同济大学污染控制与资源化研究国家重点实验室

【摘要】 采用催化微电解—UASB组合工艺处理羧甲基纤维素(CMC)生产废水,考察了废水pH、反应时间、温度、停留时间对COD去除率的影响。结果表明,当系统进水COD为20g/L时,在铁炭微电解反应器进水pH值为3.5、反应时间为75min及UASB反应器温度为37℃、厌氧停留时间为44h的条件下,出水COD<1200mg/L,为后续好氧生化处理出水达标排放奠定了基础。

【Abstract】 The catalytic microelectrolysis/UASB process was used to treat wastewater from carboxymethyl cellulose(CMC) production.The effect of pH,reaction time,temperature and hydraulic retention time on the removal rate of COD was investigated.The results show that under the conditions of raw wastewater pH of 3.5,reaction time of 75 min,UASB temperature of 37 ℃ and HRT of 44 h,the COD concentration can be reduced from 20 000 mg/L in the influent to 1 200 mg/L in the effluent.The process lays a foundation for the subsequent aerobic treatment.

  • 【文献出处】 中国给水排水 ,China Water & Wastewater , 编辑部邮箱 ,2009年03期
  • 【分类号】X703
  • 【被引频次】9
  • 【下载频次】349
节点文献中: 

本文链接的文献网络图示:

本文的引文网络