节点文献
不同前处理方法对ICP-AES测定枸杞元素含量的影响
Effect of Different Front Processing Methed on the Determination Result of 11 Elements in Medlar by ICP-AES
【摘要】 用ICP-AES测定中药材枸杞中锌、铅、锰、铁、铬、镁、钙、铜、钠、钾、镉11种元素。比较了常规湿法消化法、高压消化罐法和微波消解法处理样品对测定结果的影响。研究结果表明,高压消化罐法和微波消解处理样品,精密度和回收率较好。在选定的实验条件下,各元素间互不干扰,可在同一样品液中进行多种元素的分别测定。利用该方法测定其回收率在92.9%—101.0%之间,相对标准偏差在0.72%—2.40%之间。
【Abstract】 The effect s of different digestive methods including the wet digestion,digested in a closed teflon vessel and microwave digestion methods were compared.Many trace elements in medlar were determined by ICP-AES.The results show that the RSD and recovery are better if the medlar were digested with digested in a closed teflon vessel and microwave digestion methods.Among the many elements determined from the medlar,Zn,Pb,Mn,Fe,Cr,Mg,Ca,Cu,Na,K and Cd are the dominant chemicals.RSDs of the method were in range of 0.72%—2.40% and recoveries were in the range of 92.9%—101.0%.
- 【文献出处】 光谱实验室 ,Chinese Journal of Spectroscopy Laboratory , 编辑部邮箱 ,2009年03期
- 【分类号】R284
- 【被引频次】9
- 【下载频次】227