电站锅炉回转式空气预热器的磨损监测模型

Wear Monitoring Model for Rotary Air Preheater in Utility Boiler

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘建全孙保民郭亚斌张胜利白涛

【Author】 LIU Jian-quan~1,SUN Bao-min~1,GUO Ya-bin~2,ZHANG Sheng-li~2,BAI Tao~1(1.School of Energy and Power Engineering,North China Electric Power University,Beijing 102206,China;2.Inner Mongolia Datang International Tuoketuo Power Generation Co.,Ltd.,Hohhot 010200,China)

【机构】 华北电力大学能源与动力工程学院内蒙古大唐国际托克托发电有限责任公司

【摘要】 基于蓄热元件磨损程度与蓄热量及烟风阻力的关系,将各影响因素量化后,提出了蓄热元件磨损折算传热量和磨损折算压差的概念,推导了磨损检测的计算模型.根据空气预热器设计参数及数据采集系统(CIS)相关实时参数,实现了600 MW燃煤机组锅炉回转式空气预热器蓄热元件磨损状态的在线检测,为空气预热器的改进与计划大修提供数据依据.

【Abstract】 Based on the relationship among wearing degree of the heat storage element,heat stored,air and flue gas resistance,the concepts of converted heat transferred of the heat storage element due to wear and converted pressure difference due to wear were presented after all the influential factors were quantified.The calculation model for wear detection was derived.According to the design parameters of the air preheater and related real-time data from data collecting system(CIS),the on-line detection for wear status of the heat storage elements of the rotary air preheater of 600 MW coal fired boiler can be realized,providing reference data for modification and scheduled overhaul of the air preheater.