节点文献

用于贮存核废料混凝土断裂能的影响因素分析

Analysis of Influencing Factor on Fracture Energy of Concrete Containers for Nuclear Waste

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 李艺梁磊赵文王国峰

【Author】 LI Yi1,LIANG Lei1,2,ZHAO Wen1,WANG Guo-feng1(1.School of Resources & Civil Engineering,Northeastern University,Shenyang 110004,China;2.The Urban and Rural Committee for Construction of Panjin,Panjin 124010,China.)

【机构】 东北大学资源与土木工程学院盘锦市城乡规划建设委员会

【摘要】 为确保核废料贮存的长期耐久性,参照国际材料与结构联合会标准(RILEM),分别在常温和受热150℃后,对混杂纤维混凝土和素高强混凝土进行三点弯曲试验.结果表明:1)受热前,纤维混凝土的断裂能为素高强混凝土SP-13的6.3~12.0倍;受热后,为其12.0~16.7倍;2)大尺寸钢纤维A和C对混凝土能量吸收方面的作用优于小尺寸钢纤维B和聚丙烯纤维;钢纤维C(剪切压痕型)对混凝土断裂能的改善效果优于钢纤维A(剪切螺纹型)和钢纤维B(超短超细型);3)综合利用弯曲韧性指标以及断裂能极差、方差对比分析,钢纤维A和C适用于核废料混凝土容器材料.

【Abstract】 The antifracture property of concrete container for nuclear waste was investigated to ensure its long-time durability.According to RILEM Standard the three-point-bending test was carried out comparatively for the hybrid fiber reinforced concrete and the plain high-strength concrete(SP-13) at normal temperature and after 150 ℃ heating.The results showed that the fracture energy of the former is 6.3~12.0 times higher than the latter before heating and 12.0~16.7 times higher than the latter after heating.The big-size steel fibers(types A and C) are superior to both the small-size steel fibers(type B) and polypropylene fibers in absorbing fracture energy,and the type C steel fibers(shear-indented type) is superior to type A(shear-threaded type)and type B(ultra-short/fine type)in improving the fracture energy.Based on the comprehensive flexure toughness index and the comparative analyses of range and variance,a conclusion is drawn that the types A and C are applicable to the materials to make concrete containers for nuclear waste.

【基金】 国家自然科学基金资助项目(50508008);辽宁省博士启动基金资助项目(20041014);东北大学博士后科研基金资助项目(20060125);辽宁省自然科学基金资助项目(20082024)
  • 【文献出处】 东北大学学报(自然科学版) ,Journal of Northeastern University(Natural Science) , 编辑部邮箱 ,2009年03期