牵引变电所无功补偿的优化配置

Optimal reactive compensation in traction substation

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张嵩泰

【Author】 ZHANG Song-tai(Campus Planning Office,Southwest Jiaotong University,Chengdu 610031,China)

【机构】 西南交通大学校园规划建设处

【摘要】 在总的无功补偿容量一定的情况下,补偿容量在各补偿端口的不同分配,负序电流存在一个最低点,即固定并联电容补偿在各补偿端口的不同分配存在一个最佳容量配置点.建立固定补偿容量优化配置的数学模型,采用广义拉格朗日乘子法对补偿容量的配置进行优化设计.并用牵引变电所实测数据验证了所给方法的有效性.

【Abstract】 In the reactive power compensation of traction substation with given compensation capacity,there is a minimum negative sequence current for different distribution of compensation capacity at the compensation ports.In order to calculate the optimal configuration of the fixed compensation with minimum negative sequence current,the mathematic model of optimal configuration of the fixed compensation is established,and the configuration of compensation capacity is optimized using generalized Lagrange Method of multipliers.On site measurements in traction substation shows effectiveness of the proposed approach.

  • 【文献出处】 电力科学与技术学报 ,Journal of Electric Power Science and Technology , 编辑部邮箱 ,2009年02期
  • 【分类号】TM922.4
  • 【被引频次】2