节点文献

生物膜法净化低浓度SO2气体的工艺条件研究

On the technical conditions of low-concentrated SO2 removal by biological membrane

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 周小兰孙佩石王洁杨常亮邓辅唐王恒颖常学秀袁睿佳

【Author】 ZHOU Xiao-Ian~(1,2), SUN Pei-shi~1, WANG Jie~1, YANG Chang-liang~1,DENG Fu-tang~1, WANG Heng-ying~2, CHANG Xue-xiu~2,YUAN Rui-jia~2(1 Academe of Environment & Lake, Yunnan University, Kunming650091, China; 2 College of Life Sciences, Yunnan University,Kunming 650091, China)

【机构】 云南大学环境与湖泊研究院云南大学生命科学学院

【摘要】 采用生物膜填料塔净化低浓度SO2气体,研究其适宜工艺条件。结果表明,SO2进口气体质量浓度2 500-3 500 mg/m3、气体流量0.1 m3/h、循环液流量10-12 L/h、24℃、循环液pH<1.7时,生物膜填料塔对SO2的净化效率可达97.2%以上,对SO2生化去除量达52-56mg/(L·h)。本研究为生物法脱除烟气中低浓度SO2提供了参考。

【Abstract】 The paper is aimed at reporting our study findings on the technical conditions of low-concentrated SO2 removal by biological membrane in the laboratory. As is known, sulfur dioxide can be removed as nutrition for the biomass concurrent in the biological trickling filter. It can be changed into sulfuric acid, sulfur and cell matter of the biomass, which grows up with the sulfur dioxide to be removal from the imitated flue gas. The said imitated flue gas would go in counter current with the cycling fluid as it moves from the lower position to the higher one through the biological trickling filter, which is designed and made in our group. The conditional parameters of our study can be illustrated as follows: sulfur dioxide mass concentration, gas flux, cycling fluid runoff, temperature and pH value of the cycling fluid. In our experiments, sulfur dioxide mass concentration proves to range from 1 000 mg/m to 5 000 mg/m3, while the gas flux ranges from 0.1 m3/h to 0.4 m3/h. With the range of cycling fluid runoff from 4 L/h to 14 L/h, the temperature should be kept from 18℃ to 24℃. In addition, the cycling fluid’ s pH value ranges from 1.4 to 1.9. Our experimental study has now brought about positive results, indicating that the suitable conditions of the study should stand 2 500-3 500 mg/m3 of sulfur dioxide mass concentration, with gas flux being 0.1 m3/h, the cycling fluid runoff being 10-12 L/h and the room temperature being 24℃ and the pH value of the cycling fluid < 1.7. The sulfur dioxide removal efficiency tends to be able to reach 97.2% with the sulfur dioxide biological removal quantity rising to 52-56 mg/(L·h) under suitable conditions. Thus, the result can be taken as a valuable reference to low-concentrated sulfur dioxide removal in the flue gas.

【基金】 国家863计划项目(2007AA06Z312);国家自然科学基金项目(50478116)
  • 【文献出处】 安全与环境学报 ,Journal of Safety and Environment , 编辑部邮箱 ,2009年03期
  • 【分类号】X701.3
  • 【被引频次】4
  • 【下载频次】40
节点文献中: 

本文链接的文献网络图示:

本文的引文网络