节点文献

Failure analysis of polycrystalline diamond compact cutters for breaking rock by bending waves theory

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 龚声武赵伏军

【Author】 GONG Sheng-wu1, ZHAO Fu-jun2 (1. School of Resources and Safety Engineering, Central South University, Changsha 410083, China; 2. School of Energy and Safety Engineering, Hunan University of Science and Technology, Xiangtan 411201, China)

【机构】 School of Resources and Safety Engineering Central South UniversitySchool of Energy and Safety Engineering Hunan University of Science and TechnologyChangsha 410083 ChinaXiangtan 411201 China

【摘要】 The breakage mechanism of the polycrystalline diamond compact(PDC) cutters was analyzed by the energy theory of bending waves. The cutting tests of granite block were conducted on a multifunctional testing device by using the cutter at three kinds of negative fore angles of 30°, 45° and 60°. The results show that, when the edge of the PDC layer is broken, the layer of tungsten cobalt is broken a little under the angle of 30°, while the layer of tungsten cobalt is broken continuously under the angle of 60°, their maximum depths are about 2 and 7 mm respectively in the two cases. The eccentric distance mainly depends on the negative fore angle of the cutter. When the cutter thrusts into the rock under an attack angle of 60°, the energy of bending waves reaches the maximum since the eccentric distance is the maximum. So the damage of cutter is the most serious. This test result is consistent with the conclusion of theoretical analysis well. The eccentric distance from the axial line of cutter to the point of action between the rock and cutter has great effect on the breakage of the cutter. Thus during the process of cutting, the eccentric distance should be reduced to improve the service life of PDC cutters.

【Abstract】 The breakage mechanism of the polycrystalline diamond compact(PDC) cutters was analyzed by the energy theory of bending waves. The cutting tests of granite block were conducted on a multifunctional testing device by using the cutter at three kinds of negative fore angles of 30°, 45° and 60°. The results show that, when the edge of the PDC layer is broken, the layer of tungsten cobalt is broken a little under the angle of 30°, while the layer of tungsten cobalt is broken continuously under the angle of 60°, their maximum depths are about 2 and 7 mm respectively in the two cases. The eccentric distance mainly depends on the negative fore angle of the cutter. When the cutter thrusts into the rock under an attack angle of 60°, the energy of bending waves reaches the maximum since the eccentric distance is the maximum. So the damage of cutter is the most serious. This test result is consistent with the conclusion of theoretical analysis well. The eccentric distance from the axial line of cutter to the point of action between the rock and cutter has great effect on the breakage of the cutter. Thus during the process of cutting, the eccentric distance should be reduced to improve the service life of PDC cutters.

【基金】 Project(06JJ20094) supported by the Natural Science Foundation of Hunan Province, China
  • 【文献出处】 Journal of Central South University of Technology ,中南工业大学学报(英文版) , 编辑部邮箱 ,2008年01期
  • 【分类号】TG48
  • 【被引频次】6
  • 【下载频次】109
节点文献中: 

本文链接的文献网络图示:

本文的引文网络