新型根管治疗灭菌器的研制与开发
A New Canal Instrument Sterilizer:Research and Developevment
【摘要】 目的研制开发一种适合对根管治疗小器械快速灭菌的灭菌器。方法仿照日本SL灭菌器的工作原理制造出新型根管治疗灭菌器,检测其升温情况,用细菌培养法检测其灭菌效果,并与高温高压消毒效果进行比较。结果新型根管治疗灭菌器接通电源208.8 s可以达到设定温度(285±3)℃,7 s的灭菌效果与高温高压(Eurouda灭菌器E6-18/24)无区别。结论新型根管治疗灭菌器消毒灭菌效果可靠。
【Abstract】 OBJECTIVE To make a new sterilizer to disinfect the instruments used for the root pulp treatment.METHODS After studying the SL sterilizer used in Japan,a new sterilizer was made.Studied how long the sterilizer could be used after putting through the electric.The effect of it was compared with the Eurouda sterilizer E6-18/24 by the method of culturing the bacteria.RESULTS 208.8 seconds after putting through the electric,the sterilizer could be used to sterilize the apparatus.And the effect of the new sterilizer was the same as the Eurouda sterilizer E6-18/24.CONCLUSIONS The effect of the sterilizer is testified,and the sterilizer could be used for the root pulp treatment instruments.
- 【文献出处】 中华医院感染学杂志 ,Chinese Journal of Nosocomiology , 编辑部邮箱 ,2008年02期
- 【分类号】R187
- 【被引频次】3
- 【下载频次】45