节点文献

冷轧乳化液废水电凝聚处理研究

Treatment of Cold Rolling Plant Emulsion Wastewater by Electrocoagulation

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 张振林王海林杨绿

【Author】 ZHANG Zhen-lin WANG Hai-lin YANG Lü(Central Iron and Steel Research Institute,Beijing 100081,China)

【机构】 钢铁研究总院钢铁研究总院 北京 100081北京 100081

【摘要】 研究了用电凝聚法处理冷轧乳化液废水的可行性,对比了直流电凝聚与交流电凝聚处理乳化液废水的效果,考查了直流条件下电流密度、电极间距、pH值、电凝聚时间等因素对COD、浊度去除效果的影响。研究结果表明,在相同操作条件下直流电凝聚去除COD、浊度的效果均优于交流电凝聚处理。直流电凝聚在电流密度为30 mA/cm~2、电极间距为5 mm、pH值为5、处理时间为45 min条件下,去除COD与浊度的效果均最佳,去除率分别达到90.75%和99.76%。

【Abstract】 The possibility of electrocoagulation treatment on cold rolling plant emulsion wastewater has been stud- ied.The treatment effects of emulsion wastewater by DC eleetrocoagulation have been compared with AC electro- coagulation.The effects of current density,electrode gap,pH and electrolysis time on percent removal of COD and turbidity have been investigated.According to the results,the removal efficiency of both COD and turbidity by DC electrocoagulation were higher than by AC electrocoagulation.The removal efficiency of COD and turbidity which were 90.75% and 99.76% respectively represented good effects in the condition of current density 30 mA/cm~2 ,electrode gap 5 mm ,pH 5 and electrolysis time 45 rain while using DC power

  • 【分类号】X703
  • 【被引频次】6
  • 【下载频次】211
节点文献中: 

本文链接的文献网络图示:

本文的引文网络