基于Aperture-based优化方式对鼻咽癌调强计划设计的探讨
Discussion of IMRT for Nasopharyngeal Carcinoma Based on Optimized Aperture-based Plan
【摘要】 目的:探讨和总结使用Aperture-based逆向计划完成鼻咽癌调强计划设计,所能达到的计划质量及计划设计经验。方法:使用医科达Precise计划系统对24例鼻咽癌进行调强计划设计,每个计划设计9个大野,PGTV、PCTV1和PCTV2的处方剂量分别为68 ̄70、60和54 Gy。结果:PGTV和PCTV1 95%以上体积达到处方剂量。脑干、脊髓、左右晶体和左右腮腺的最大量平均分别为55、41、6.1和34.8 Gy。结论:使用Aperture-based完成的根治性鼻咽癌调强计划,其计划质量符合临床要求,但对于套环型靶区,在PGTV与PCTV1之间的剂量梯度未能压缩得很好。
【Abstract】 Objective To evaluate and summarize a design of backward IMRT plan for nasopharyngeal carcinoma with Aperture-based plan.Methods The IMRT plan was designed with ELEKTA Precise plan system based on 24 cases.Each plan had 9 fields shapes.The recipe dose of PGTV,PCTV1 and PCTV2 are 68-70,60 and 54Gy.Results 95% volume of PGTV and PCTV1 reach the recipe dose.The maximum average of brain stem,spinal cord,left and right crystalloid and parotid are 55,41,6.1 and 34.8Gy respectively.Conclusion The IMRT plan by Aperture-based for nasopharyngeal carcinoma is in accordance with the clinical demands.But toward the lantern ring target,the dose grads are not very well between PGTV and PCTV1.
【Key words】 backward plan by Aperture-based; plan quality; design experience;