节点文献

多接收器电感耦合等离子体质谱法测定镉标准溶液中镉的同位素组成

Measurement of Cadmium Isotopic Composition of Standard Solutions by Multi-collector Inductively Coupled Plasma Mass Spectrometry

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 高博梁细荣刘颖胡光黔曾文涂湘林

【Author】 GAO Bo1,2,LIANG Xi-rong3,LIU Ying3,HU Guang-qian3,ZENG Wen3,TU Xiang-lin3 (1.State Key Laboratory of Organic Geochemistry,Guangzhou Institute of Geochemistry,Chinese Academy of Sciences,Guangzhou 510640,China;2.Graduate University of Chinese Academy of Sciences,Beijing 100049,China;3.Key Laboratory of Isotope Geochronology and Geochemistry,Guangzhou Institute of Geochemistry,Chinese Academy of Sciences,Guangzhou 510640,China)

【机构】 中国科学院广州地球化学研究所有机地球化学国家重点实验室中国科学院广州地球化学研究所同位素年代学与地球化学重点实验室

【摘要】 建立了多接收器电感耦合等离子体质谱仪对Cd标准溶液同位素组成进行分析的实验方法。仪器的质量分馏校正采用Standard-Sample Bracketing法。实验结果用δ114/110Cd来表达。在此研究基础上,以SPEX Cd标准溶液为参考标准,对国外4种Cd标准溶液进行了测定。结果表明,实验测定的精度在0.07‰~0.13‰(δ114/110Cd),与目前文献报道的结果具有相似的精度。以最新SPEX Cd标准样品(δ114/110Cd=0)为基准,计算的δ114/110CdJMC、δ114/110CdSPEX-1、δ114/110CdBAM1012和δ114/110CdM櫣nster的值分别为0.55‰、0.56‰、-0.65‰和5.14‰,说明不同批次SPEX标准溶液的Cd同位素组成是明显不同的,最新的SPEX Cd标准溶液与SPEX-1 Cd的δ114/110Cd值存在着0.56‰的差别。将以SPEX Cd为参考标准的δ114/110CdBAM1012和δ114/110CdM櫣nster转化为以SPEX-1或JMC为参考标准后,得到的结果与文献报道的结果在误差范围内一致。

【Abstract】 A method for precise isotopic analysis was presented in this paper.Measurement of Cd isotopic composition was carried out by multi-collector inductively coupled plasma mass spectrometry(MC-ICPMS),using standard-sample bracketing technology for mass bias correction.The Cd isotopic data were reported relative to SPEX Cd standard solution and expressed as the δ114/110Cd.Four Cd standard solutions(JMC,SPEX-1,BAM-1012 and Münster) were repeatedly measured and accurate and reproducible Cd isotopic results were obtained in order to assess the accuracy of the measurements.The results showed that the precision for Cd solution measurements was 0.07‰~0.13‰(δ114/110Cd).The values of δ114/110Cd measured for the JMC,SPEX-1,BAM-1012 and Münster relative to the SPEX standard solution(δ114/110Cd=0) were 0.55‰,0.56‰,-0.65‰ and 5.14‰ respectively.It indicated that the Cd isotopic composition from different batches of SEPX was different and the variation of δ114/110Cd between SPEX and SPEX-1 was 0.56‰.Considering this difference of Cd standards between SPEX and SPEX-1,the δ114/110Cd of Münster and BAM-1012 relative to SPEX were identical to the values measured in other studies,relative to SPEX-1 solution or JMC solution,when taking into account the uncertainty.

【基金】 中国科学院广州地球化学研究所知识创新工程领域前沿项目资助(GIGCX-03-06)
  • 【文献出处】 岩矿测试 ,Rock and Mineral Analysis , 编辑部邮箱 ,2008年05期
  • 【分类号】O614.242
  • 【被引频次】5