节点文献

血球计数仪血小板检测结果减低原因的探讨

Investigation on the Causes Reducing Platelet in Tests by Blood Cell Counter

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 汪虹彬黄德元

【Author】 WANG Hong-bin,HUANG De-yuan (The People’s Hospital of Puning,Puning,Guangdong 515300,China)

【机构】 普宁市人民医院

【摘要】 目的:探讨血球计数仪检测血小板减低的原因。方法:对我院2007年1月至12月560例血常规检查血小板结果减低的病人标本作配对t检验。结果:146例标本用血球计数仪和显微镜计数法所测得结果较一致P>0.05,差异无显著性。414例标本用两种方法测得结果相差较大,P<0.01,差异有显著性。结论:用两种方法测得血小板结果相差较大的多为血小板假性减低。

【Abstract】 Objective To investigate the causes why platelet decreased in tests by blood cell counter.Methods Match and compare 560 samples collected in our hospital from Jan. 2007 to Dec. 2007,in which platelet decreased in blood routine inspection.Results The results of 146 cases tested by blood cell counter and microscope counting method quite agreed (P>0. 05),while the results of 414 cases tested in the same way quite disagreed (P<0.01).Conclusion That platelet decreased in the results which quite disagreed with each other is mostly not true.

  • 【文献出处】 实用医技杂志 ,Journal of Practical Medical Techniques , 编辑部邮箱 ,2008年32期
  • 【分类号】R446.113
  • 【被引频次】2
  • 【下载频次】40
节点文献中: 

本文链接的文献网络图示:

本文的引文网络