节点文献

燃煤电厂烟气脱硫存在的问题和建议

CONSIDERATION FOR FGD DESIGN IN COAL-FIRED POWER PLANT

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 方志星周祖飞

【Author】 FANG Zhi-xing~1,ZHOU Zu-fei~2 (1.Zhejiang Provincial Energy Group Co.,Ltd,Hangzhou 310007,China; 2.Zhejiang Electric Power Research Institute,Hangzhou 310014,China)

【机构】 浙江省能源集团有限公司浙江省电力试验研究院

【摘要】 针对燃煤电厂已投运湿法烟气脱硫系统普遍存在的问题,结合有关法规要求,从技术可靠性和经济性角度分析火电厂烟气脱硫项目决策和工艺选择时应注意的问题,提出设计合理的脱硫效率、选取准确的原始烟气参数、配置可靠的系统设备等方面的建议,以优化烟气脱硫系统的设计。

【Abstract】 Based on the disadvantage of the running wet flue gas desulfurization(FGD) system in coal-fired power plant and linking correlative law and criterion,some problems were studied about decision-making and choosing technique of FGD projects from the technology reliability and economization. In order to optimize the designing of FGD,some suggestion were also involved in which confirming the reasonable desulfurize efficiency,selecting the exact original parameters of flue gas and equipping reliable device.

【关键词】 烟气脱硫脱硫率设计建议
【Key words】 flue gas desulfurizationdesulfurize efficiencydesignsuggestion