节点文献

薄型铜冷却壁的热性能

Thermal Performance of Thinner Copper Cooling Stave

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 吴狄峰程树森潘宏伟

【Author】 WU Di-feng,CHENG Shu-sen,PAN Hong-wei(School of Metallurgical and Ecological Engineering,University of Science and Technology Beijing,Beijing 100083,China)

【机构】 北京科技大学冶金与生态工程学院北京科技大学冶金与生态工程学院 北京100083北京100083

【摘要】 为了降低高炉铜冷却壁的造价,开发了一种厚度为90 mm的薄型铜冷却壁。通过热态试验测量了高温下冷却壁的温度分布和冷面应变分布,通过数值模拟计算了冷却壁的温度场和应力应变场。热态试验和数值模拟结果符合较好。研究结果表明,薄型铜冷却壁能承受的最大热负荷为220 kW/m2,在高炉炉况下的基体温度以及由此产生的热应力都不足以使其破坏,满足长寿高炉的要求。

【Abstract】 A new type of thinner blast furnace copper cooling stave whose thickness was 90 mm was developed to decrease its cost.The strain of cold surface and temperature of the stave under high thermal load were measured through thermal test,and the fields of temperature,strain and stress were also calculated through numerical simulation.The results of these two methods were consistent with each other well,which indicated that the thinner copper stave could bear the maximum heat flux of 220 kW/m2,and both the temperature and stress of the stave under blast furnace operating condition were insufficient to destroy itself.It could satisfy the requirement of long campaign.

【基金】 国家自然科学基金资助项目(60472095)
  • 【文献出处】 钢铁研究学报 ,Journal of Iron and Steel Research , 编辑部邮箱 ,2008年04期
  • 【分类号】TF573
  • 【被引频次】5
  • 【下载频次】143
节点文献中: 

本文链接的文献网络图示:

本文的引文网络