【摘要】 采用强电磁场环境模拟与防护技术,选择两种工业电雷管,分别在37.5MHz5、0MHz、144MHz以及450MHz频率点对理论推算出来的工业电雷管防射频安全距离进行试验验证。结果表明:试样在10倍的安全场强辐照下均未发火,证明推算出来的工业电雷管防射频安全距离是正确的。
【Abstract】 Based on the strong electromagnetism emulation and protection technique,two kinds of commercial electric detonator were selected as samples,and the calculated safety distance of anti-RF for samples were verified at four frequency points,which were 37.5MHz,50MHz,144MHz and 450MHz.The results showed that with 10 times as much as safety field intensity of radiation,the electric detonator didn’t fire.The verification proved that the computation is right.