节点文献

对工业电雷管防射频安全距离计算结果的试验验证

Verify Tests on the Safety Distance of Anti-RF for Commercial Electric Detonator

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 杜斌颜事龙孙霖封青梅

【Author】 DU Bin1,YAN Shi-long1,SUN Lin2,FENG Qing-mei2(1.Department of Chemical Engineering,Anhui University of Science and Technology,Huainan,232001;2.The 213 Research Institute of China Ordnance Industry,Xi’an,710061)

【机构】 安徽理工大学化学工程学院中国兵器工业第213研究所中国兵器工业第213研究所 安徽淮南232001安徽淮南232001陕西西安710061

【摘要】 采用强电磁场环境模拟与防护技术,选择两种工业电雷管,分别在37.5MHz5、0MHz、144MHz以及450MHz频率点对理论推算出来的工业电雷管防射频安全距离进行试验验证。结果表明:试样在10倍的安全场强辐照下均未发火,证明推算出来的工业电雷管防射频安全距离是正确的。

【Abstract】 Based on the strong electromagnetism emulation and protection technique,two kinds of commercial electric detonator were selected as samples,and the calculated safety distance of anti-RF for samples were verified at four frequency points,which were 37.5MHz,50MHz,144MHz and 450MHz.The results showed that with 10 times as much as safety field intensity of radiation,the electric detonator didn’t fire.The verification proved that the computation is right.

  • 【文献出处】 火工品 ,Initiators & Pyrotechnics , 编辑部邮箱 ,2008年01期
  • 【分类号】TJ452.3
  • 【被引频次】1
  • 【下载频次】142
节点文献中: 

本文链接的文献网络图示:

本文的引文网络