节点文献
燃煤锅炉等离子点火启动特点分析
Analysis on the Characteristics of Plasma Ignition for Coal-fired Boiler
【摘要】 介绍了广州恒运电厂210 MW和国华台山电厂600 MW锅炉等离子点火启动的特点。结合锅炉的调试,重点对锅炉等离子点火启动的运行经验和发现的问题进行了分析和总结。分析结果对于采用等离子点火技术的锅炉有参考价值。
【Abstract】 This paper introduces the characteristics of plasma ignition for coal-fired boiler in 210 MW unit in Guangzhou Hengyun power plant and in 600 MW unit in Guohua Taishan power plant.On the basis of the commissioning of boiler,the operative experiences and the problems of boiler’s plasma ignition and its startup processes are summarized and analysed.All the analytical results are valuable to the boiler with the plasma ignition system.
- 【文献出处】 锅炉技术 ,Boiler Technology , 编辑部邮箱 ,2008年05期