景德镇475t/h循环流化床锅炉过热屏超温原因分析及改进措施
Cause Analysis and Improvement Measure for Superheated Panel Overheating of 475 t/h Circulating Fluidized Bed Boiler in Jingdezhen Power Plant
【摘要】 根据锅炉运行数据,对景德镇475 t/h循环流化床锅炉在启动过程中屏式过热器超温的原因进行了分析,得出其超温的原因主要是:①炉膛水冷壁的传热特性差;②锅炉运行参数严重偏离设计参数;③锅炉转向室的吸热比设计值高.同时,提出将部分过热屏改造成水冷屏的改进措施,经实际运行表明:改造后低温屏的温度有所降低,该方案基本上达到了预期效果.
【Abstract】 The causes of panel superheater overheating during the start-up of the 475 t/h circulating fluidized bed boiler in Jingdezhen Power Plant are analyzed according to the operational data.It is concluded that the principal causes of overheating are bad heat-transfer performance of furnace water-wall,deviation of operational parameters from design parameters as well as high heat-absorbing amount of boiler reversing chamber compared with the design value.Meanwhile the retrofit countermeasure is presented,which replaces part of the superheated panels by water-cooled panels.The practical operation shows that the temperature of low temperature panel decreases after retrofit,which indicate that the desired result is achieved.
【Key words】 energy and power engineering; circulating fluidized bed; superheated panel; overheating; water circulation;
- 【文献出处】 动力工程 ,Journal of Power Engineering , 编辑部邮箱 ,2008年06期
- 【分类号】TK223.32
- 【被引频次】2
- 【下载频次】68