节点文献
混合供电负荷下选择性漏电保护的研究
The Research of Selective Leakage Protection for Mix-Power Supply Load
【摘要】 在分析了井下三相三线制配电网实现选择性漏电保护原理的基础上,提出了三相与单相负荷混合供电线路实现选择性漏电保护的原理,并进行了理论分析、Matlab仿真及各项实验。现场运行情况表明,采用该原理实现了可靠的选择性漏电保护。
【Abstract】 Based onthe analysis of the theory to realize selective leakage protection for a three-phase three-wire distribution network system, a theory to realize selective leakage protection for a mix-power supply load systemis proposed containing three-phase and single-phase load . The theoretical analysis , Matlab si mulation, various experiment with emphasis are made.The running conditions on spot indicates that this theory can realize selective leakage protection reliably.
- 【文献出处】 电气应用 ,Electrotechnical Application , 编辑部邮箱 ,2008年16期
- 【分类号】TM564
- 【被引频次】1
- 【下载频次】115