节点文献

大坝测压管观测资料分析在北邢家水库渗流安全评价中的应用

Application of dam piezometer pipe data analysis in seepage safety assessment of Beixingjia reservoir

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 季安姜葵红牟燕妮于文蓬兰昊

【Author】 JI An,JIANG Kui-hong,MOU Yan-ni and et al.//Shandong Water Conservancy Survey and Design Institute

【机构】 山东省水利勘测设计院

【摘要】 通过对北邢家水库大坝测压管观测资料进行综合分析,结合日常检查及地质勘察资料,判断出部分坝段粘土心墙存在填筑不均匀与防渗性能差的质量问题,发现了部分坝段存在坝体上游水位长期高于库水位的渗流异常现象,并将测压管资料绘制的大坝浸润线与渗流计算的浸润线进行对比,对理论计算采用的渗透系数予以验证。

【Abstract】 By data analysis of dam piezometer pipe,combined with routine inspection and geological survey of Beixingjia reservoir,the quality problem of bad filling and high permeability of the clay core wall was found.Also,the problem that dam upstream water level was higher than reservoir water level exists at some dam blocks.This paper compared the measured phreatic line to calculative phreatic line,and verified the seepage coefficient adopted in theory analysis.

【关键词】 测压管渗流浸润线相关性
【Key words】 piezometer pipeseepagephreatic linecorrelation
  • 【分类号】TV698.1
  • 【被引频次】5
  • 【下载频次】91
节点文献中: 

本文链接的文献网络图示:

本文的引文网络