节点文献

屈肌腱损伤手术中针头临时固定肌腱的改进

The Improvement of Tendon Temporary Fixation with Syringe Needle for Treatment of Flexor Tendon Injury

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 郭明珂彭秀晴张经歧王洲吴军段亚飞窦志

【Author】 GUO Mingke,PENG Xiuqing,ZHANG Jingqi,et al.Department of Orthopaedics,the 260 th Hospital of PLA,Shijiazhuang 050041,China

【机构】 解放军第260医院外五科河北省人民医院河北医科大学第三医院手外科

【摘要】 目的改进屈肌腱损伤手术中针头临时固定肌腱的方法。方法52例患者67条屈肌腱损伤修复术中采用针头贯穿伤口近侧皮肤固定肌腱近端、贯穿伤口远侧皮肤固定肌腱远端的方法修复肌腱损伤,术后随访2~8个月,观察手部功能恢复情况。结果手术操作简便,易于肌腱修复,术后TAM法评定疗效优良率达83.0%。结论该改进方法优点突出,方便实用,值得推广。

【Abstract】 Objective To improve the tendon temporary fixation with syringe needle treatment for flexor tendon injury.Methods 52 cases(67 fingers) of tenorrhaphy were collected.All cases were treated with the improved method of tendons temporary fixation with syringe needle,i.e.fixing the proximal repairing tendon through the proximal skin of the wound with syringe needle and the distal tendon through the distal skin in tenorrhaphy.All the cases were followed up for 2-8 months and functional recovery degrees of the fingers were examined.Results The improved method of tendons temporary fixation was convenient to repair tendon injury.The effective rate of functional recovery was 83.0%.Conclusion The improved method is simple and practical,so deserves to be promoted.

【关键词】 屈肌腱损伤肌腱修复术
【Key words】 Flexor tendonInjuryTenorrhaphy
  • 【文献出处】 白求恩军医学院学报 ,Journal of Bethune Military Medical College , 编辑部邮箱 ,2008年04期
  • 【分类号】R687.2
  • 【被引频次】2
  • 【下载频次】35
节点文献中: 

本文链接的文献网络图示:

本文的引文网络