高压交联聚乙烯电力电缆水树枝缺陷在线监测系统的研制
Research and development of HV XLPE cable water-tree fault on-line monitoring
【摘要】 文中提出"非谐振"叠加的方法,实现了电力电缆的在线监测。该方法通过在电缆的绝缘层上叠加1个101H z的交流信号,再检测电缆绝缘屏蔽层上1H z的特征信号。现场应用表明,系统分析诊断正确,运行稳定可靠。
【Abstract】 A non-resonant superposition method was presented to realize power cable on-line monitoring.A 101Hz AC signal was added on the insulator layer of cables and a 1Hz characteristic signal on insulator shielding layer was detected.Practical application indicated that monitoring system was stable and diagnosed correctly.
- 【文献出处】 湖南电力 ,Hunan Electric Power , 编辑部邮箱 ,2007年06期
- 【分类号】TM247;TP274.5
- 【被引频次】6
- 【下载频次】180