节点文献

用瞬态脉冲试验研究射频试验后电火工品的性能变化

Investigation on the Performance Variation of Electric Explosive Devices (EEDs) Experienced RF Injection with Transient Pulse Test

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 周彬秦志春陈西武徐振相

【Author】 ZHOU Bin,QIN Zhi-chun,CHEN Xi-wu,XU Zhen-xiang(College of Chemical Engineering,Nanjing University of Science and Technology,Nanjing,210094)

【机构】 南京理工大学化工学院南京理工大学化工学院 江苏南京210094江苏南京210094

【摘要】 介绍了瞬态脉冲试验原理,利用瞬态脉冲试验研究了电火工品经过射频作用后发火性能的变化,发火试验的结果说明:射频试验功率越大,温升越高,火工品的平均发火作用时间就越长。研究结果表明瞬态脉冲试验能够反映电火工品受射频能量作用后的性能变化。

【Abstract】 The principle of transient pulse test has been proposed and the performance variation of electric explosive devices(EEDs) experienced radio frequency(RF) injection has been investigated.It has been observed that,when the employed RF power is larger,the temperature rise of the EEDs is higher and the function time of the EEDs is longer.The experimental results have showed that transient pulse test can reflect the performance change of EEDs experienced RF injection.

  • 【文献出处】 火工品 ,Initiators & Pyrotechnics , 编辑部邮箱 ,2007年06期
  • 【分类号】TJ450.6
  • 【被引频次】3
  • 【下载频次】97
节点文献中: 

本文链接的文献网络图示:

本文的引文网络