节点文献

Design of a Rogowski Coil with a Magnetic Core Used for Measurements of Nanosecond Current Pulses

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 朱俊栋张乔根贾江波陶风波杨连殿杨兰均

【Author】 ZHU Jundong ZHANG Qiaogen JIA Jiangbo TAO Fengbo YANG Liandian YANG Lanjun State Key Laboratory of Electrical Insulation and Power Equipment,Xi’an Jiaotong University,Xi’an 710049,China

【机构】 State Key Laboratory of Electrical Insulation and Power Equipment,Xi’an Jiaotong University,Xi’an 710049,China

【摘要】 <正> A Rogowski coil is developed to detect the nanosecond pulse signals of the dischargecurrent with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Perfor-mance tests show that the Rogowski coil has both excellent dynamic and static characteristics.Calibrating results and the comparison between the standard current shunt and the developed Ro-gowski coil for the measurement of nanosecond discharge pulses demonstrate that the developedRogowski coil can reproduce the actual waveform of the discharge current accurately.

【Abstract】 A Rogowski coil is developed to detect the nanosecond pulse signals of the discharge current with a wide bandwidth of 800 kHz to 106 MHz and high sensitivity of 2.22 V/A. Perfor- mance tests show that the Rogowski coil has both excellent dynamic and static characteristics. Calibrating results and the comparison between the standard current shunt and the developed Ro- gowski coil for the measurement of nanosecond discharge pulses demonstrate that the developed Rogowski coil can reproduce the actual waveform of the discharge current accurately.

【基金】 supported by National Natural Science Foundation of China (No.50477027)
  • 【文献出处】 Plasma Science and Technology ,等离子体科学和技术(英文版) , 编辑部邮箱 ,2006年04期
  • 【分类号】O441
  • 【被引频次】8
  • 【下载频次】23
节点文献中: 

本文链接的文献网络图示:

本文的引文网络