节点文献
生物接触氧化技术在生活小区污水处理中的应用
Application of Biological Contact Oxidation to Residential District Waste water Treatment
【摘要】 利用悬挂式软性纤维填料制备了生物接触氧化塔,并对生活小区污水进行处理,三个月的试验结果,表明:在HRT=3h的条件下,当原水COD在300~400mg/L,氨氮在30~80mg/L范围时,出水氨氮<1mg/L、COD<50mg/L、SS<15mg/L,此时,系统硝化负荷最高达0.50kg/(m3·d)有机负荷最高达3.2kg/(m3·d)。由实验结果得出,HRT为1.5h,在有机负荷2kg/(m3·d)时,水力负荷是影响硝化的关键因素。
【Abstract】 Bio-contact oxidation tower with hanging fibre media was used to treat the wastewater of a residential district.When HRT is 3h,COD is between 300 and 400 mg/L and NH3-N between 30 and 80 mg/L in the influene,after treatment COD decreased to 50mg/L,NH3-N<1 mg/L and SS<15mg/L in the efluent in case of maximal nitrogen load 0.5kg/(m3·d )and maximal organic load 3.2kg/(m3·d). The results showed when organic load 2.0kg/(m3·d),the hydraulic load is the key factor for nitrofication,and HRT must be greater than 1.5h.
【Key words】 biological contact oxidation wastewater treatment hydraulic load organic load;
- 【文献出处】 净水技术 ,Water Purification Technology , 编辑部邮箱 ,2005年04期
- 【分类号】X703.1
- 【被引频次】27
- 【下载频次】703