节点文献
二氧化氯发生器对饮用水消毒效果观察
OBSERVATION ON EFFICACY OF CHLORINE DIOXIDE GENERATOR IN DISINFECTING DRINKING WATER
【摘要】 用悬液定量法观察了二氧化氯发生器产生的二氧化氯消毒液杀灭水中微生物效果与影响因素。结果,以含二氧化氯 0. 375mg/L和 0. 25mg/L,分别作用 1min和 5min,可使水中大肠杆菌降至 0cfu/100ml,其杀菌作用随水温的升高而增强,随水中腐植酸等有机物的增多而降低,当水的pH值在 6. 5~8. 5时,对其杀菌效果无影响。
【Abstract】 Suspension quantitative method was used to observe the efficacy of chlorine dioxide disinfectant solution generated by the chlorine dioxide generator in killing microorganisms in water and its influencing factors. Results: The chlorine dioxide 0.375 mg/L and 0.25 mg/L with a 1 min contact time and 5 min contact time respectively could reduce Escherichia coli in water to 0 cfu/100ml. Its germicidal efficacy increased with increasing water temperature and decreased with increasing organic substances such as humic acid in water. pH value of water at 6.5~8.5 had no influence on germicidal efficacy.
【Key words】 chlorine dioxide generator; disinfection of drinking water; Escherichia coli;
- 【文献出处】 中国消毒学杂志 ,Chinese Journal of Disinfection , 编辑部邮箱 ,2005年01期
- 【分类号】R123.1
- 【被引频次】12