风机盘管干湿工况等价法热力计算研究

Study on wet-dry cooling conditions equivalent method of fan-coil unit

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 倪美琴马荣生谢治祥

【Author】 NI Mei-qin,MA Rong-sheng,XIE Zhi-xiang(Coll of Environ Sci & Engin,Yangzhou Univ,Yangzhou 225009,China)

【机构】 扬州大学环境科学与工程学院扬州大学环境科学与工程学院 江苏扬州225009江苏扬州225009

【摘要】 利用等价干工况的概念,提出了风机盘管机组在湿工况下的一种热力计算方法——干湿工况等价法,并在各种工况下进行了实验验证,实验结果与计算结果吻合得非常好,这表明该方法物理意义明确,计算方法简便,计算精度较高.

【Abstract】 With the concept of equivalent dry cooling condition,this paper puts forward wet-dry cooling conditions equivalent method which is a new thermodynamic calculation method of FCU under wet cooling condition.According to the experimental results which are performed in various cooling conditions,the results fit very well with ones from calculation.It is found that its improvement is clear in physical meaning and is simpler in calculation and of higher precision.

【基金】 江苏省建设厅基金资助项目(JS200246)
  • 【文献出处】 扬州大学学报(自然科学版) ,Journal of Yangzhou University(Natural Science Edition) , 编辑部邮箱 ,2005年04期