节点文献
并联型有源滤波器的死区效应及其补偿策略研究
Study on Dead-Time Effect of the Parallel Active Power Filter and Its Compensation Strategies
【摘要】 分析了三相四线制有源电力滤波器中逆变器的死区效应对其补偿性能的影响,研究了电流反馈控制和无死区控制两种补偿策略用于上述有源电力滤波器死区补偿的可行性,并通过仿真对两种方法的补偿效果进行比较。结果表明,两者均能有效补偿死区效应的影响;但在实现的难易程度和成本方面,无死区控制策略有一定优势。
【Abstract】 This paper analyzes the dead-time effects of the inverter in 3-phase 4-wire active power filter and its influence on the compensation performance of the APF.Study on the feasibility of adopting two kinds of dead-time effect compensation strategies-current feedback and no dead-time to the APF is also presented.The simulation results show that both strategies can compensate the influence effectively.However,the strategy of no dead-time provides certain superiority in the light of the complexity and cost.
【关键词】 有源电力滤波器;
死区效应;
电流反馈型补偿;
无死区补偿;
【Key words】 active power filter; dead-time effect; current feedback compensation; no dead-time compensation;
【Key words】 active power filter; dead-time effect; current feedback compensation; no dead-time compensation;
- 【文献出处】 通信电源技术 ,Telecom Power Technologies , 编辑部邮箱 ,2005年05期
- 【分类号】TN713
- 【被引频次】7
- 【下载频次】269