The mass flow of the secondary flow and pressure loss in the chamber was measured experimentally. Then, the pressure loss measured was used as a numerical boundary condition to simulate the 3-D flow in the injector with pressure loss by finite volume methods. Good agreements are made when comparing the experimental mass flow of secondary flow with the numerical results and the maximum relative error is less than 4%, which shows that the numerical algorithm is feasible and correct. Based on the investigation...