酵母菌污染膜的超声波辅助清洗技术

ULTRASONIC CLEANING OF PVDF MEMBRANE FOULED BY MICROZYME

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王晓丽陈蕊冯真真高博傅学起

【Author】 Wang Xiao-li, Chen Rui, Feng Zhen-zhen, Gao Bo, Fu Xue-qi (College of Environmental Science & Engineering, Nankai University, Tianjin 300071, China)

【机构】 南开大学环境科学与工程学院南开大学环境科学与工程学院 天津300071天津300071天津300071

【摘要】 超声波清洗技术用于清洗10g/L酵母菌溶液污染的聚偏氟乙烯(PVDF)微滤膜。实验中所用的超声波频率为40kHz,超声波的强度为1.43~2.85W/cm2。实验结果表明:超声波水洗是恢复其水通量的有效方法。超声波强度越高,达到相同的清洗时间较短。而超声波清洗时水溶液温度越高,超声波的清洗效果反而下降。

【Abstract】 An ultrasonic cleaning technique was applied to removal of fouling of PVDF microfiltration membrane, as 10g/L yeast solution was permeated for 120 min by dead-end filtration. The ultrasound employed had a 40 kHz and the output power of 1.43~2.85 W/cm2. For PVDF membrane, cleaning experiments were carried out with two methods by water cleaning with and without ultrasonic irradiation. It is found that water cleaning with ultrasonic treatment is an effective method for the recovery of water flux. The recovery rate (FR)of the fouled membrane can be achieved in a short time with high ultrasound intensity. The FR, however , may decrease with the rising of cleaning temperature.

【关键词】 超声波微滤膜清洗菌体污染
【Key words】 ultrasoundmicrofiltration membranecleaningfouled by microzyme
  • 【文献出处】 水处理技术 ,Technology of Water Treatment , 编辑部邮箱 ,2005年07期
  • 【分类号】TQ028.8
  • 【被引频次】16
  • 【下载频次】157