【摘要】 建立了转轮除湿复合式空调系统能耗的数学模型,并对其能耗进行计算与分析,结果表明:除湿能耗是影响总能耗的重要因素,采用新风先除湿再与回风混合的方式、室内排风作再生空气均可减小除湿能耗,降低总能耗;与传统空调系统相比,转轮除湿复合式空调系统具有较大的节能潜力,湿负荷越大,其优越性越明显。
【Abstract】 An energy consumption numerical model was developed.The calculation and analysis proves that energy consumption of dehumidification is an important factor affecting the total,and it can reduce the total energy consumption by adopting the method that fresh air is dehumidified before mixed with return air,or indoor exhaust is used as regeneration air.Compared with the conventional air conditioning system,the hybrid air conditioning system can save energy,and more humidity load,more energy saving potential.
【关键词】 复合式空调;
能耗;
除湿转轮;
节能;
【Key words】 hybrid air conditioning system; energy consumption; a rotary desiccant wheel; energy saving;