节点文献
上海南站钢屋盖结构性能化抗火安全评估
Analysis of the Fire Safety of the Steel Roof Construction of Shanghai South Railway Station
【摘要】 上海铁路南站是上海市重要的对外交通枢纽和市内换乘枢纽。由于站台和大厅采用超大空间的建筑布局,超出了国内现有建筑防火设计规范的规定。特别对于南站钢屋盖这样重要的钢结构,国内现有规范方法难以满足抗火安全性与经济性要求。本文基于性能化对南站钢结构屋盖的抗火安全性进行了评估。在评估分析中首先确定结构抗火性能目标,然后对钢屋盖结构在可能最不利火灾下的性能进行分析,最后根据结构的受火性能是否满足抗火性能目标来评估结构的抗火安全性及需要采取的防火保护措施。本文结果被业主和消防主管部门采纳,可供类似工程的结构抗火设计参考。
【Abstract】 The Shanghai south railway station is the pivotal position of the traffic in Shanghai.Because the ultra-large space in the building is beyond the specifications of the fire safety design codes,especially for such an important steel building,it is hard to satisfy the safety and economic requirement according to the national standards.In this paper,the safety of the steel roof structure of Shanghai railway station is analyzed with the performance-based method.Firstly,the target of fire-resistance of the structure is determined,then the steel roof structure in the most dangerous potential fire situation is analyzed.At the last,depending on if the target of fire-resistance is met,the fire safety of the steel roof structure is analyzed and the protection method is determined.The result of the analysis is adopted by the building owner and the fire department,and can be referenced for the fire safety design of similar buildings.
- 【文献出处】 建筑钢结构进展 ,Progress in Steal Building Structures , 编辑部邮箱 ,2005年02期
- 【分类号】TU393
- 【被引频次】37
- 【下载频次】423