节点文献
Methods of measurement for the beam-based alignment System in HLS
【Abstract】 The beam-based alignment system is given in HLS (Hefei Light Source), in which a switchable shunt resistorwas installed on quadrupole to bypass a small percentage of the magnet current. The system can measureBPM-to-quadrupole offset which can be used to position the beam in the magnetic center of quadrupoles. In measurement,some methods ( linear fitting with single corrector, parabola fitting with single corrector, linear fitting withlocal bump, and parabola fitting with local bump ) are used. These measurement results are given, and comparedamong the methods mentioned above.
【关键词】 Beam-based alignment;
BPM-to-quadrupole offset;
Linear fitting;
Parabola fitting;
Local bump;
【Key words】 Beam-based alignment; BPM-to-quadrupole offset; Linear fitting; Parabola fitting; Local bump;
【Key words】 Beam-based alignment; BPM-to-quadrupole offset; Linear fitting; Parabola fitting; Local bump;
【基金】 SupportedbyNationalNaturalScienceFoundationofChina(10275062)
- 【文献出处】 Nuclear Science and Techniques ,核技术(英文版) , 编辑部邮箱 ,2005年06期
- 【分类号】O572.211