节点文献
接触氧化-人工湿地去除印染废水中的COD
COD removal in dyeing wastewater with contact oxidation and artificial wetland
【摘要】 采用絮凝沉淀+接触氧化+人工湿地工艺处理印染废水中COD研究。结果表明,斜板沉淀池出水COD平均值为1322mg/L,此间COD去除率为38·6%;二沉池出水COD平均值为71mg/L,此段COD去除率达94·6%;人工湿地出水COD平均值为37mg/L,人工湿地COD去除率为48·0%。处理设施COD总去除率98·3%。
【Abstract】 COD removal from dyeing wastewater with flocculation+contact oxidation+artificial wetland process was studied. The results showed that the effluent concentrations of COD from flocculation, contact oxidation and artificial wetland process were 1322 mg/L, 71 mg/L, and 37 mg/L, the removal rates of COD were 38.6%, 94.6% and 48.0%respectively. Total removal rate of the disposal system was 98.3%.
【关键词】 印染废水;
废水处理;
接触氧化;
人工湿地;
【Key words】 dyeing wastewater; wastewater treatment; contact oxidation; artificial wetland;
【Key words】 dyeing wastewater; wastewater treatment; contact oxidation; artificial wetland;
- 【文献出处】 环境污染治理技术与设备 ,Techniques and Equipment for Environmental Pollution Control , 编辑部邮箱 ,2005年09期
- 【分类号】X791
- 【被引频次】9
- 【下载频次】352