承船厢厢头门水封漏水原因分析及处理
Analysis on Cause of Exceeding Standard Leakage through Gate Seal of Carrying Vessel of Geheyan Ship-lift & Treatment Plan for It
【摘要】 隔河岩第一级升船机承船厢厢头门为下沉式平面闸门,在充水过程中发现漏水量超出《水利水电钢闸门制造安装及验收规范》DL/T5018-94的要求,经过试验和分析,采取有针对性的处理措施,解决了厢头门止水泄漏问题。
【Abstract】 The drop plate gate is installed at each end of the carrying vessel of Geheyan ship-lift.The leakage through gate seal exceeds the standard rate of DL/T5018-94《Manufacture,Installation,Acceptance Specification of Steel Gate of Water Conservancy & Hydropower》.Through test analysis,the cause of leakage is found out and a treatment plan for it is drawn up.
- 【文献出处】 湖北水力发电 ,Hubei Watero Power , 编辑部邮箱 ,2005年04期
- 【分类号】U642
- 【被引频次】1
- 【下载频次】31