地铁火灾中强制通风烟控系统作用的模拟

Simulation of Effect of Forced Ventilated and Smoke Controlled System in Subway Fire Disaster

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 蔡波李辉亮廖光煊

【Author】 Cai Bo1, Li Huiliang2, Liao Guangxuan1(1. University of Science and Technology of China,Hefei 230027,China; 2.Shenzhen Fire Department,Shenzhen,Guangdong 518031,China)

【机构】 中国科学技术大学深圳市公安消防局中国科学技术大学 合肥230027深圳518031合肥230027

【摘要】 地铁火灾比地面火灾具有更大的危险性。通过对地铁火灾的模拟可以重现火灾过程,研究火灾现象,分析火灾原因。通过FDS模拟,对比大邱市地铁火灾在有无强制通风烟控系统条件下,火灾现场的温度场和烟尘分布,研究讨论其对控制地铁火灾的重要作用。

【Abstract】 Subway fire disaster is more hazardous than overground fire. Daegu underground railway fire disaster in Korea leads to a disastrous result. By means of fire simulation, recurrence of fire process, fire phenomenon and its reason could be studied. Based on FDS, the distribution of temperature and smoke with or without forced ventilated and smoke controlled system in Daegu subway fire are compared, and the effect on subway fire disaster control is also discussed in this paper.

【基金】 国家自然科学基金重点专项基金资助项目(50323005)
  • 【文献出处】 中国工程科学 ,Engineering Science , 编辑部邮箱 ,2005年08期
  • 【分类号】U231.96
  • 【被引频次】41
  • 【下载频次】524
节点文献中: 

本文链接的文献网络图示:

本文的引文网络