节点文献
HC型微量硫分析仪标定方法的改进
Improvement of calibration method for model HC trace sulfur analyzer
【摘要】 针对HC型微量硫分析仪标定中出现的问题,改进了标定方法,采用与甲醇合成原料气组分相同的标准混合气作为稀释气,使分析结果更加准确。
【Abstract】 In view of errors in calibrating model HC trace sulfur analyzer, the calibration method was improved. The calibration gas was diluted with standard mixed gas with the same components of methanol synthetic raw materials. The analytical results were accurate by using the improved method.
- 【文献出处】 分析仪器 ,Analytical Instrumentation , 编辑部邮箱 ,2005年03期
- 【分类号】TH83
- 【被引频次】1
- 【下载频次】42