The mechanism of corrosion of limestone-gypsum glue gas desulfurization systems and techniques for its prevention are being discussed. Design requirement for corrosion prevention of different parts of the system and their execution are explained, together with some ideas concerning further development of preventive requirements and prevention techniques are being presented.