节点文献

300MW锅炉高温再热器超温问题的试验及分析

Experiment and Investigation of Overheating Problem of 300MW Boiler’s HT Reheater

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 王英涛丘纪华陈刚周英彪陈越赵小峰

【Author】 WANG Ying-tao,QIU Ji-hua,CHEN Gang,et al.

【机构】 华中科技大学湛江发电厂湛江发电厂

【摘要】 针对湛江发电厂Ⅰ期工程300MW锅炉长期存在高温再热器管局部超温、再热器出口两侧汽温偏差大等问题。通过高温再热器的进、出口的冷态流场试验及进口温度分布的测试,分析了再热器管产生超温和气温偏差的原因,并结合再热器管的布置进行了说明。

【Abstract】 The No.1 300MW boiler in Zhanjiang Power Plant has had the problems of local overheating of high temperature reheater and large steam temperature deviation at the exit of reheaters for a long time.According to the cold test of flow field at the high temperature reheaters’ entrance and exit and the hot test of temperature field at it’s entrance,the cause of reheater’s overheating and steam temperature deviation is analyzed and an explanation associating with the structure of reheater’s tubes is made.

【关键词】 再热器超温锅炉烟温偏差
【Key words】 reheateroverheatingboilerflue-gas temperature deviation
  • 【文献出处】 电站系统工程 ,Power System Engineering , 编辑部邮箱 ,2005年06期
  • 【分类号】TK223.32
  • 【被引频次】3
  • 【下载频次】144
节点文献中: 

本文链接的文献网络图示:

本文的引文网络