节点文献

凝汽器铜管氨腐蚀的研究

Experimental Study on Corrosion of Condenser Copper Tubes in Ammonia

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 朱志平黄可龙周琼花杨道武陈恳

【Author】 ZHU Zhi-ping 1.2, HUANG Ke-long1, ZHOU Qiong-hua2, YANG Dao wu2, Chen Ken2 (1.College of Chemistry and Chemical Engineering , Central South University, Changsha 410083; 2. Department of Chemistry and Environmental Engineering, Changsha University of Science & Technology, Changsha 410077, China).

【机构】 中南大学化学化工学院长沙理工大学化学与环境工程系长沙理工大学化学与环境工程系 湖南长沙410083长沙理工大学化学与环境工程系湖南长沙410077湖南长沙410083湖南长沙410077

【摘要】 研究了影响凝汽器铜管氨腐蚀的因素与规律,以确定防止凝汽器氨腐蚀的途径。将HAl772A铜管管样在10种氨浓度、两种溶解氧浓度的溶液中浸泡45d,测定溶液的溶解氧变化情况,用失重法、原子吸收法测定铜管管样腐蚀速率;在6种温度、两种溶解氧、4种氨浓度条件下研究温度对铜管腐蚀速率的影响。氨液浓度小于800mg/L时,铜管氨腐蚀轻微,氨液浓度为800~1000mg/L时铜管腐蚀速率明显增大,且随氨液浓度的增大而增加;开口状态下铜管腐蚀速率比闭口时大,温度升高时同一氨液浓度下铜管腐蚀速率增大。凝汽器铜管氨腐蚀主要影响因素是溶解氧与氨液浓度,氨液浓度超过800mg/L后,腐蚀速率随氨浓度、氧含量、温度的增加而增大;用失重法与原子吸收法测定铜管腐蚀速率基本一致。

【Abstract】 The factors affecting the corrosion of condensor copper tubes in ammonia and the relevant rules were investigated. Thus the HAl77-2A copper tube samples were soaked in ammonia solutions of different ammonia concentrations (500~20 000 mg/L) and different dissolved O2 concentrations (open and close state) at room temperature for 45 d, and the variation in the dissolved oxygen of the ammonia solution was measured. At the same time, the corrosion rate of the copper tube samples was determined by corrosion mass loss measuring and atomic absorption spectroscopic analysis. Moreover, the influence of temperature on the corrosion behavior of the copper tube samples was investigated at different temperatures (20~45 ℃), different dissolved O2 concentrations (open and close state), and different ammonia concentrations as well. It was found that the copper tube samples had a slight corrosion at an ammonia concentration below 800 mg/L. The corrosion rate of the copper tube samples significantly increased with increasing ammonia concentration within 800~1 000 mg/L and with increasing temperature at a fixed ammonia concentration as well. Besides, they recorded a larger corrosion rate in open system than in closed system. The corrosion behavior of the condenser copper tube was largely dependent on the concentrations of the dissolved O2 and ammonia. The corrosion rate increased with increasing concentration of the ammonia and dissolved oxygen and water temperature as well. Moreover, the corrosion rate determined by corrosion mass loss was similar to that determined by atomic absorption spectroscopy.

【基金】 湖南省教育厅科研资助项目(02C068);湖南省自然科学基金资助项目(01JJY3027)
  • 【文献出处】 材料保护 ,Materials Protection , 编辑部邮箱 ,2005年07期
  • 【分类号】TG172
  • 【被引频次】13
  • 【下载频次】286
节点文献中: 

本文链接的文献网络图示:

本文的引文网络