节点文献
RP-HPLC法测定盐酸利多卡因注射液含量—中国药典(2000版)和美国药典(27版)方法的比较
The determination of the content of lidocaine by RP-HPLC:comparison of the determination method of ChP(2000 version) and USP(27 version)
【摘要】 目的用反相高效液相色谱法(RP-HPLC)测定盐酸利多卡因注射液含量,并将中国药典(2000版)与美国药典(27版)两种方法进行比较。方法用两国药典方法(反相高效液相色谱法)测定盐酸利多卡因注射液含量。中国药典(2000版)色谱条件:C1 8柱,以醋酸钠溶液-甲醇(40∶60)为流动相,检测波长254 nm。美国药典(27版)色谱条件:C1 8柱,以醋酸钠溶液-乙腈(4∶1)为流动相,检测波长254 nm。结果中国药典(2000版)方法盐酸利多卡因在0.1~3.0 g.L-1浓度范围内,浓度与峰面积线性关系良好,相关系数r=0.999 9。美国药典(27版)方法盐酸利多卡因在0.1~3.0 g.L-1浓度范围内,浓度与峰面积线性关系良好,相关系数r=0.999 8。结论二者盐酸利多卡因浓度与峰面积均具有良好的线性关系,峰面积相差不大,无明显差别。
【Abstract】 Aim The content of lidocaine was determined by RP-HPLC of different mobile phase with comparison of Chp(2000 version) and USP(27 version).Methods The content of lidocaine was determined by using the RPHPLC method.The chromatographic conditions at the Chp included the C18 column and the mobile phase was composed of sodium acetate-methanol(40∶60).The detection wavelength was 254 nm.The chromatographic conditions at the USP included the C18 column and the mobile phase was composed of sodium acetate -acetonitrile(4∶1).The detection wavelength was 254 nm.Results The linearity was obtained over 0.13.0 g·L-1(r =0.999 9) for lidocaine at the Chp(2000 version) and the linear relation was good.At the USP(27 version) the linearity was obtained over 0.13.0 g·L-1(r =0.999 8) and the linear relation was good.Conclusion The two linear relations were very good with the density and the peak area.By compareson with the USP,the peak area of the ChP is similar.There is no distinct differences between the two methods.
- 【文献出处】 安徽医药 ,Anhui Medical and Pharmaceutical Journal , 编辑部邮箱 ,2005年09期
- 【分类号】R927
- 【被引频次】4
- 【下载频次】214