检测SARS患者血清中抗-SARS-CoV IgG的四种试剂盒比较

Comparison among four kits in detection of anti--CoV IgG in sera of SARS patients

  • 推荐 CAJ下载
  • PDF下载
  • 不支持迅雷等下载工具,请取消加速工具后下载。

【作者】 刘学恩李杰李永华王玲李彤陆海英王广发朱万孚高晓明王佑春赵振东徐小元庄辉

【Author】 LIU Xue-en;LI Jie;LI Yong-hua;WANG Ling; LI Tong;LU Hai-ying;WANG Guang-fa;ZHU Wan-fu;GAO Xiao-ming;WANG You-chun;ZHAO Zhen-dong;XU Xiao-yuan;ZHUANG Hui.Department of Microbiology,Peking University Health Science Center,Beijing 100083,China Corresponding author: ZHUANG Hui.

【机构】 北京大学基础医学院病原生物学系中国药品生物制品检定所北京大学基础医学院病原生物学系 100083100083100083

【摘要】 目的 比较4种试剂盒检测SARS患者血清中抗-SARS-CoV IgG的灵敏度和特异度。方法 用2种酶联免疫吸附试验(EIA)和2种间接免疫荧光法(IFA)试剂盒分别检测18例SARS患者的99份系列血清及123份阴性参比血清标本中抗-SARS-CoV IgG。结果 在患者发病第1周,4种试剂盒均未检出抗-SARS-CoV IgG;自发病第2周,除EIA甲未能检出外,EIA乙和2种IFA均从血清中检出抗-SARS-CoV IgG,其阳性率分别为57.1%(4/7)、57.1%(4/7)和42.9%(3/7)。4种试剂盒最早检出时间分别为发病后第16、12、13和9天。于发病后第3周该4种试剂盒的检出率分别为52.6%(10/19)、94.7%(18/19)、78.9%(15/19)和84.2%(16/19)。但自发病第4周后,该4种试剂盒的检出率相同。检测123份阴性参比血清表明,除EIA乙的特异度为94.9%外,其余3种试剂盒的特异度均为100%。结论 2种IFA的灵敏度和特异度均较2种EIA高;2种国产EIA试剂盒质量尚需进一步提高。

【Abstract】 Objective To compare the senstivity and specificity of four kits for detection of anti-severe acute respiratory syndrome(SARS)-CoV IgG in sera of SARS patients. Methods Anti-SARS-CoVIgG was detected in 99 serial sera from 18 SARS patients and in 123 negative reference sera, using twoenzyme linked immunosorbent assays (EIA No. A and No. B) and two indirect immunofluoresecence assays(Australian IFA and Euroimmun IFA). Results Anti-SARS-CoV IgG was not detected in sera collectedfrom SARS patients at the first week after onset by any of the four kits, however, it was detectable in seraobtained at the second week of illness by EIA No. B, and two IFA, but not by ELA No. A, with thepositive rates of 57. 1% (4/7), 57. 1% (4/7) and 42. 9% (3/7), respectively. The anti-SARS-CoV IgG wasfirst determined in sera on the 9th day by Euroimmun IFA, 12th day by EIA No. B, 13th day byAustralian IFA, and 16th day by EIA No. A. The positive rates of antiboody on the 3rd week after onsetwere 84. 2% (16/19), 94. 7% (18/19), 78. 9% (15/19) ana 52. 6% (10/19) respectively. They wereidentical since the 4th week after the disease onset. Through detection of 123 negative reference sera, thespecificity of EIA No. A and two IFA was 100%, with exception of 94. 9% for EIA No. B. ConclusionThe sensitivity and specficity of the two IFAs were relatively higher than that of the two EIAs. Thequality of the two homemade EIAs should be improved.

  • 【文献出处】 中华流行病学杂志 ,Chinese Journal of Epidemiology , 编辑部邮箱 ,2004年06期
  • 【分类号】R511.9
  • 【被引频次】1
  • 【下载频次】112
节点文献中: 

本文链接的文献网络图示:

本文的引文网络