节点文献
冷却储存环主环注入线四极磁铁测量
Measurements of the quadrupoles for cooler-storage-ring injection beam line
【摘要】 介绍了兰州重离子加速器冷却储存环工程主环注入线四极磁铁谐波测磁系统和谐波磁场测量结果。分析了磁铁误差产生的原因以及磁铁加工存在的问题和注意事项
【Abstract】 The rotating coil measurement system and the measurement results of quadrupoles for CSRm injection beam line are introduced. The reasons causing the high order harmonic components are analyzed. The short circuit of magnet coils will cause sextupole component and the twists of magnet core will affect the octupole component. Otherwise, the chamfering also makes a great impact on the sextupole and octupole components, and some results are involved too.
【关键词】 磁场测量;
四极磁铁;
旋转线圈;
高阶误差量;
分散性;
【Key words】 Magnetic measurement; Quadrupole; Rotating coil; High order harmonic components; Magnet dispersion;
【Key words】 Magnetic measurement; Quadrupole; Rotating coil; High order harmonic components; Magnet dispersion;
【基金】 国家大科学工程——兰州重离子加速器冷却储存环 (HIRFL CSR)项目资助课题
- 【文献出处】 强激光与粒子束 ,High Power Laser & Particle Beams , 编辑部邮箱 ,2004年06期
- 【分类号】TL503.9
- 【下载频次】98